Excalibur Water Systems 2.0" High Capacity Premium Flow Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Distributeurs d'eau Excalibur Water Systems 2.0" High Capacity Premium Flow Series. Excalibur WatEr SyStEmS 2.0” HiGH caPacity SuPEr FlOW SEriES Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 38
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
EXCALIBUR WATER SYSTEMS
2.0” HIGH CAPACITY SUPER FLOW SERIES
DUPLEX WATER SOFTENER
Installation and Operations Manual
142 Commerce Park Drive,
Units M-O, Barrie ON L4N 8W8
www.excaliburwater.com
Vue de la page 0
1 2 3 4 5 6 ... 37 38

Résumé du contenu

Page 1 - DUPLEX WATER SOFTENER

EXCALIBUR WATER SYSTEMS 2.0” HIGH CAPACITY SUPER FLOW SERIES DUPLEX WATER SOFTENERInstallation and Operations Manual142 Commerce Park Drive, Units M-

Page 2

19Water softener 3 and 4 unit systems with optional systems boards for water softener relay outputs and separate inlet (4 water softeners shown)

Page 3

110Water Softener Programming Screen Quick Reference:1. Water softener individual screen descriptions are detailed on the following pages.2. Some wate

Page 6

113Water softener set time accessed by pressing set lock while in the water softener user screen. Use the up and down water softener arrows to scroll

Page 7 - 2 Water Softener System:

114Water softener displays days remaining does not display if days override is set to OFF. The water softener days remaining can be decremented one da

Page 8

115Water softener displays total water softener volume since install/reset individually re-settable using history reset sequence.Water softener displ

Page 9

116Water softener select country US or SI. This sets the water softener use of 12 or 24 hour clock and the water softener display of gallons or litres

Page 10

117Single water softeners have a selection of hard water bypass, no hard water bypass or water softener relay operation. When the water softeners star

Page 11

118Installer 1:Set water softener volumetric capacity or OFF. OFF will not be an option if the water softener day control is set to OFF. x 1000 wate

Page 12

112.0” High Capacity Premium Flow Series Water Softener:Premium flow water softener AC adapter for European use.1. Water softener 220 - 240 VAC 50Hz in

Page 13

119Installer 4:Select water softener time of regen. Use water softener up and down arrows to scroll minutes.Installer 5:Select water softener time of

Page 14

120System Setup 6:Select water softener regeneration typeWater softener delayed (DEL-1) Water softener delayed (DEL-2) Water softener delayed (DEL-3)

Page 15

121System Setup 9:Select water softener meter type or pulses. Water softener 2.0 meter (type) Water softener 1.5 meter (type) Water softener system pu

Page 16

122Timer 1 - A:Select water softener time of cycle 1.The water softener press next and down reset from this screen unlocks the setup screens.The follo

Page 17

123Timer 1 - B2Select water softener timer of alternate regen cycle 2.

Page 18

124Timer 2:Set water softener output 1, these water softener settings will only be allowed with water softener system board installed.Time: Water soft

Page 19 - After 5 Minutes:

125Timer 3:Set water softener output 2, these water softener settings will only be allowed with water softener system board installed.Time: The water

Page 20

126Timer 4:Select water softener output 1. On water softener trigger set point per water softener previously selected. This water softener screen will

Page 21

127Timer 6:Select water softener output 2, on water softener trigger set point, per water softener previously selected. This water softener screen wil

Page 22

128Timer 7:Select water softener output 2 on duration before turning off. This water softener screen will not display if the water softener does not h

Page 23 - Operation After 5 Minutes:

12Water Softener Custom Meter Wiring:1. Water softener terminate end with a Molex series 2695 housing, Pin 22-01-3037 and (3) Molex series 41572 (or 4

Page 24 - Timer 1 - B2

129Water softener returns to normal operation after 5 minutes.Water softener is accessed by pressing water softener next and down buttons simultaneous

Page 25

130Water softener cycle setup 2.Water softener select regeneration repeats, 1 - 10 or OFF. Water softener repeats regeneration cycle sequence 1 as sel

Page 26

131Return water softener to normal operation after 5 minutes.Water softener is accessed by pressing water softener next and down buttons simultaneousl

Page 27

132Water softener gallons usedWater softener volume used within the water softener selected hour.Water softener automatically togglesWater softener au

Page 28

133Water softener diagnostics 5 The water softener maximum flow rate for the last 28 days.Water softener diagnostic 5 - B The water history of maximum

Page 29 - Timer 7:

134Water softener diagnostics 6 Water softener total volume through the water softener.Water softener diagnostics 7 Water softener system totalizer f

Page 30

135Water softener automatically togglesWater softener total system flow for the selected hourWater Softener Diagnostic Screens Continued:

Page 31

136Water Softener Valve History:Water softener returns to normal operation after 5 minutes non resettableWater softener accessed by pressing water sof

Page 32

137Water Softener Error Codes:

Page 33

13Water Softener Optional System Board:Water softener system board required for relay output and separate source inlet.1) Water softener relay outlets

Page 34

14Water Softener Motorized Drive Operation:Viewing the water softener piston rod through the clear water softener clear dome is a visual indicator of

Page 35

15Water Softener Reversing Motorized Drive Direction:Water softener motorized bypass and water softener MAV drives are factory wired with the white wi

Page 36

16Water Softener Wiring Diagram Examples 2 Water Softener System:Water softener dual system with optional system optional system board for water softe

Page 37 - Water Softener Valve History:

17Water softener 3 and 4 unit systems with no optional system boards (4 water softener shown)